Compact Photoelectric Sensor | E3Z-D82 2M | Omron
Omron E3Z-D82 2M Compact Photoelectric Sensor, Highly Visible indicator. Compact size and shape. Visible beam for installation and servicing. Capable of detecting extremely small targets. Intensive shielding for high electromagnetic noise immunity.
Model: E3Z-D82 2M
Type: Compact Photoelectric Sensor
Introduction:
The E3Z-D82 2M is commonly used to detect light in various applications such as nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations. Shape, Square type. Sensing method, Diffuse-reflective. Sensing distance, White paper 300 x 300 mm: 1 m. Differential distance, 20% max. of sensing distance.
Make sure that the power supply to the Sensor is within the rated voltage range.
Do not short-circuit the load, otherwise the Sensor may be damaged.
Do not connect the power supply to the Sensor with no load connected, otherwise the internal elements may explode or burn.
It’s important to remember that when the load and sensor are connected to separate power supplies, you should always turn on the sensor before supplying power to the load. This ensures that everything operates smoothly and in the correct order.
- Always turn OFF the power supply to the Sensor before connecting or disconnecting the metal connector.
- Hold the connector cover to connect or disconnect it.
- Always tighten the connector cover by hand if using the XS3F. Do not use pliers.
- Vibration may disconnect the connector if it is not connected securely or may not maintain the proper degree of protection of the Sensor.
- When using other connectors, follow the recommended application conditions and tightening torque specs.
Mounting the Sensor
- Make sure that the optical axes are not in opposition to each other when mounting Sensors face-to-face. Otherwise, mutual interference may result.
- It’s important to install the sensor carefully to avoid direct exposure to intense light sources like sunlight, fluorescent light, or incandescent light. This will ensure optimal performance.
- Do not strike the Photoelectric Sensor with a hammer or any other tool during the installation of the Sensor, or the Sensor will lose its water-resistive properties.
- Use M3 screws to mount the Sensor.
- When mounting the case, make sure that the tightening torque applied to each screw does not exceed 0.54 N·m.
Mounting Directions
Make sure that the sensing side of the Sensor is parallel with the surface of the sensing objects. Normally, do not incline the Sensor towards the sensing object. If the object you’re sensing has a glossy surface, you can tilt the sensor by 5° to 10° as shown in the illustration. Just make sure that the sensor isn’t affected by any background objects. This adjustment will help with accurate detection.
Specification | Detail |
---|---|
Shape |
Square type |
Sensing Method | Diffuse-reflective |
Sensing Distance | White paper 300 x 300 mm: 1 m |
Differential Distance | 20% max. of sensing distance |
Light Source | Infrared LED (870 nm) |
Power Supply Voltage | 12 to 24 VDC±10% ripple (p-p) 10% max. |
Current Consumption | 30 mA max. |
Operation Mode |
Light-ON/Dark-ON select-able |
Response Time |
Operate or reset: 1 ms max. |
Sensitivity Setting |
Single-turn adjustment |
Ambient Temperature Range (Operating) | –25 to 55 ℃ (with no icing) |
Ambient Temperature Range (Storage) | -40 to 70 ℃ (with no freezing or condensation) |
Ambient Humidity Range (Operating) |
35 to 85 % (with no condensation) |
Ambient Humidity Range (Storage) | 35 to 95 % (with no condensation) |
Insulation Resistance |
20 MΩ min. (500 VDC megger) |
Dielectric Strength |
1000 VAC 50/60 Hz 1 min |
Shock Resistance |
Destruction: 500 m/s2 3 times each in X, Y and Z directions |
Degree of Protection |
IEC: IP67 |
Connection Method |
Pre-wired models (Cable length 2 m) |
Indicator |
Operation indicator (orange), Stability indicator (green) |