Function and system design FTC968 DC Nivector:

The Nivector’s face analyses the various dielectric properties of air and bulk materials while serving as a sensor for the surrounding environment. The electronics alter the switching state if the bulk solids come into touch with the face.

To ensure quiescent current functioning across all applications, set the Nivector to either a min. or max. fail-safe mode. An LED displays the switching status information. A screened electrode shields the sensor from material buildup and interference from the vessel wall.

Depending on the chosen fail-safe option and the current level, the Nivector actively switches and signals in the following situations: reaching the point level, experiencing a fault, or encountering a power failure (where the electrical switch is locked).

Application FTC968 DC Nivector

For minimum or maximum detection in silos holding free-flowing, powdery, or fine-grained bulk materials (maximum particle size 10 mm or 0,39 in), the Nivector is a very small point-level switch.

Its design and materials make the Nivector especially well-suited for installation in confined spaces and for use with food.

Zone 20 is a dangerous location for dust explosions where the Nivector FTC968Z can be employed.

Common uses include animal feed, plastic granules, detergent, grain, sugar, spices, and semolina.

Advantages of FTC968 DC Nivector

You can put the device into operation quickly and affordably without calibration. Without mechanical moving components, it has a long service life and a high level of immunity to electromagnetic interference and voltage peaks.

  • Simple control for changing status that is visible from outside the vessel
  • “Protector”-protected point level switch with functional testable
Allen-Bradley MPL-A430P-SJ72AA
If you need a specific Allen Bradley product or series, then we probably have it. Please call or email us your request.

Order via phone: (+92) 321-6707058

ENGINEERING SOLUTIONS firmly believes that Engineering is the cornerstone of high-quality life. There will be a never-ending need for products and services to harness and maximize their full potential and use. UNIBOTECH will be the best-in-class provider of top-notch engineering products and services

Input
Measured variable Level (limit, binary)
Measuring range
(detection range)
Determined by mounting point in silo
Output
Output signal Binary: Output blocked if point level is reached
The signal on the alarm Output is blocked
Load AC version
Load switched via thyristor directly into the power circuit
• Transient (40 ms) max. 1.5 A, max. 375 VA at 253 V or max. 31.5 VA at 21 V
(not resistant to short-circuit)
continuous max. 87 VA at 253 V (with FTC968Z max. 250 V), max. 7.4 VA at 21 V
min. 2.5 VA at 253 V (10 mA), min. 0.5 VA at 21 V (20 mA)
Voltage drop max. 12 V
Quiescent current max. 4 mA with blocked Thyristor
DC version
Load switched via transistor and separate PNP connection
• Transient (50 ms) max. 0.5 A, max. 55 V (resistant to cyclical overload and short-circuit)
continuous max. 350 mA;
max. 0.5 ÎĵF at 55 V, max. 1.0 ÎĵF at 24 V;
Quiescent voltage < 3 V (with connected transistor);
Quiescent current < 100 ÎĵA (with blocked transistor)
Fail-safe mode Minimum/ maximum quiescent current, switchable
MIN = Minimum safety: The output switches in a safety-oriented manner when the probe is cleared.
(Signal on alarm). Used for example for dry-running protection
MAX = Maximum safety: The output switches in a safety-oriented manner when the sensor is covered.
(Signal on alarm). Used for example for overflow protection
Switching time approx. 0.2 s after covering or clearing